56.460 | V6R (E) | Through valve with female thread, PN 16 |
|
76.321 | V6R (P) | Through valve with inside thread, PN 16 |
|
57.001 | VCL010...020 | 2-way control valve Valveco |
|
56.090 | VKR (E) | 2-way control ball valve |
|
76.110 | VUD (P) | Through flanged valve, PN 6 |
|
56.110 | VUD (E) | Through flanged valve, PN 6 |
|
76.115 | VUE (P) | Through flanged valve, PN 16/10 |
|
56.115 | VUE (E) | Through flanged valve, PN 16/10 |
|
76.120 | VUG (P) | Through flanged valve, PN 25/16 |
|
56.120 | VUG (E) | Through flanged valve, PN 25/16 |
|
55.008 | VUL (E) | Unit through valve (regulating), PN 16 |
|
56.100 | VUN (E) | Through valve with male thread, PN 16 |
|
76.122 | VUP (P) | Pressure-relieved through flanged valve, PN 25 |
|
56.122 | VUP (E) | Pressure-relieved through flanged valve, PN 25 |
|
56.125 | VUS (E) | Through flanged valve , PN 40 |
|
76.125 | VUS (P) | Through flanged valve, PN 40 |
|
55.006 | VXL (E) | Unit through valve |
|
32.040 | XAFP100 | Flow probe for use in ventilation ducts |
|
79.030 | XAP (P) | Position monitor/indicator |
|
69.010 | XEP | e/p and p/e converter |
|
69.455 | XFRP 5 | Pressure-reducing station |
|
69.300 | XGP 2 | Pneum. control-pressure adjuster (small cap.) |
|
69.310 | XGP 2L | Heavy-duty, pneumatic control-pressure |
|
69.150 | XHP 3 | Pneumatic manual switch |
|
68.470 | XMP | Manometer for indicating measured values |
|
69.400 | XP | Pneumatic restrictor |
|
46.790 | XPES | Setpoint-potentiometer |
|
69.610 | XRP 101...104 | Pneumatic relay, plug-in type |
|
79.010 | XSP 31.(P) | Pneumatic positioner |
|
69.360 | XTP 2 | Time-lag relay |
|
69.700 | XYP 1 | Pneumatic test unit |
|
69.710 | XYP 2 | Pneumatic test unit for controllers |
|
69.720 | XYP 3 | Low-pressure test unit |
|
96.700 | YYO 300 | EY3600 novaNet291 OPC Server |
|
99.401 | YZP 401 | novaPro 32 |
|
99.410 | YZP 410...431 | novaPro Open Suite |
|
99.450 | YZP 450 | novaPro EBal |
|
12.018 | ZDR | Time-switch |
|
43.160 | FCCP,FCIU | Fume cupbd function indicator+interface |
|
45.020 | FXV 006 | Electric distributor for control signals |
|
45.021 | FXV 106 | Electric distributor for heating and cooling |
|
No | Types | Title | PDS Link |
---|---|---|---|
90.520 | GZF 520 | CASE TPC (Touch panel configurator) |
|
90.520 | GZF 520 | CASE TPC (Touch panel configurator) |
|
90.900 | GZS 100 | CASE Suite |
|
No | Types | Title |
|
---|---|---|---|
69.605 | Installation | Material for pneumatic equipment |
|
60.001 | Installation | Instructions for pneumatic plants |
|
45.011 | LET 210R...380R | Radio receiver for control signals |
|
45.001 | LRT 210...310 | Room thermostat w. radio transmission |
|
45.004 | LXT 240R, 250R | Remote-control mode selector (radio) |
|
45.005 | LXT 340R | Programm. radio-contr. remote-control unit |
|
54.026 | M3R, M4R (E) | Control valve with threaded connect.,PN 10 |
|
54.015 | MH32F, MH42F (E) | Flanged mixing valve, PN 6 |
|
54.025 | MH32R, MH42R (E) | Screwed mixing valve, PN 6 |
|
43.030 | NRT 101 | Electronic room-temp. controller |
|
43.034 | NRT 105 | Electronic fan-coil controller |
|
43.036 | NRT 107 | Room- and flow-temperatur controller |
|
43.038 | NRT 114 | Electronic heating controller |
|
43.070 | NRT 210, 220 | Electronic room-temperature controller |
|
43.019 | NRT 300 | Elec. ctrlr. forair-cond'g (heat'g-cool'g) |
|
21.610 | RAK | Universal thermostat |
|
65.006 | RAP 80 | Selector relay |
|
65.007 | RAP 80 F9.. | Snap-action relay |
|
68.051 | RCP 10, 11 | PI-controller |
|
68.101 | RCP 20, 21 | P-controller |
|
68.151 | RCP 30, 31 | P+PI cascade controller |
|
68.210 | RCP 40 | Damper control unit |
|
46.103 | RDB 300 | Operating unit for RDT 300 |
|
65.010 | RDP 80 | Averaging relay |
|
46.100 | RDT 100 | Electronic ctrlr. for ventilation & air-con |
|
46.999 | RDT 200 | Electronic ctrlr. for ventilation & air-con | NO PDS |
46.102 | RDT 300 | Electronic ctrlr. for ventilation & air-con |
|
46.201 | RDT 708 | Ctrlr for vent.& air-cond for compact sys |
|
46.205 | RDT 711 | Ctrlr for vent.& air-con advanced funct's |
|
46.210 | RDT 724 | Ctrlr vent. air cond communic., universal |
|
43.125 | RLE 150 | Room-pressure controller |
|
43.124 | RLE 152 | Volume-flow controller, continuous |
|
67.301 | RLP 10 | Pneumatic volume-flow controller |
|
67.320 | RLP 10 F9.. | Pneumatic volume-flow transducer |
|
67.400 | RLP 100 | Pneumatic air-volume controller |
|
67.440 | RLP 100 F9.. | Dual-channel air-volume controller |
|
67.420 | RLP 100 F9.. | Pneum. room-pressure controller |
|
67.430 | RLP 100 F9.. | Pneumatic volume-flow transducer |
|
65.025 | RPJP 80 | PI relay |
|
68.240 | RPP 20 | P-controller |
|
65.052 | RUEP 5 | Electro-pneumatic relay |
|
68.451 | RUP | Differential-pressure controller/transducer |
|
65.150 | RVP 11 | Volume-amplifying relay |
|
65.015 | RVP 80 | Amplifying relay |
|
65.020 | RWP 80 | Reversing relay |
|
43.150 | RXE 101 | Air-volume adding unit |
|
67.500 | RXP 101 | Air-volume adding relay |
|
67.525 | RXP 200 | Pneum. Dual-channel, VAV master controller |
|
67.531 | RXP 210 | Air-volume alarm unit |
|
67.535 | RXP 212 | Pneumatic operating unit |
|
67.100 | RXP 81 | Pneumatic master controller |
|
39.001 | Schutzrohre | LW7, LW15 |
|
29.001 | Schutzrohre | LW7, LW15 |
|
32.010 | SDU 101 | Fine-differential-pressure transducer |
|
37.100 | SGU 100 F001 | Sash sensor |
|
44.535 | STU 101 | Electr. multiplier/converter for temp. data |
|
32.020 | SVU 100 | Air-flow transducer |
|
99.501 | SWMP36/24USB | novaPro |
|
43.160 | FCCP,FCIU | Fume cupbd function indicator+interface |
|
45.020 | FXV 006 | Electric distributor for control signals |
|
45.021 | FXV 106 | Electric distributor for heating and cooling |
|
No | Types | Title | PDS Link |
---|---|---|---|
90.520 | GZF 520 | CASE TPC (Touch panel configurator) |
|
90.520 | GZF 520 | CASE TPC (Touch panel configurator) |
|
90.900 | GZS 100 | CASE Suite |
|
No | Types | Title | PDS Link |
---|---|---|---|
24.022 | HBC 111, 112 | Humidistat for duct mounting |
|
24.015 | HSC 101 | Build-in humidistat |
|
24.012 | HSC 120 | Room humidistat |
|
68.410 | HSUP | Room transducer for relative humidity |
|
68.421 | HTP 151 | Duct transducer for relative humidity |
|
No | Types | Title | PDS Link |
---|---|---|---|
69.605 | Installation | Material for pneumatic equipment |
|
60.001 | Installation | Instructions for pneumatic plants |
|
45.011 | LET 210R...380R | Radio receiver for control signals |
|
45.001 | LRT 210...310 | Room thermostat w. radio transmission |
|
45.004 | LXT 240R, 250R | Remote-control mode selector (radio) |
|
45.005 | LXT 340R | Programm. radio-contr. remote-control unit |
|
54.026 | M3R, M4R (E) | Control valve with threaded connect.,PN 10 |
|
54.015 | MH32F, MH42F (E) | Flanged mixing valve, PN 6 |
|
54.025 | MH32R, MH42R (E) | Screwed mixing valve, PN 6 |
|
43.030 | NRT 101 | Electronic room-temp. controller |
|
43.034 | NRT 105 | Electronic fan-coil controller |
|
43.036 | NRT 107 | Room- and flow-temperatur controller |
|
43.038 | NRT 114 | Electronic heating controller |
|
43.070 | NRT 210, 220 | Electronic room-temperature controller |
|
43.019 | NRT 300 | Elec. ctrlr. forair-cond'g (heat'g-cool'g) |
|
21.610 | RAK | Universal thermostat |
|
65.006 | RAP 80 | Selector relay |
|
65.007 | RAP 80 F9.. | Snap-action relay |
|
68.051 | RCP 10, 11 | PI-controller |
|
68.101 | RCP 20, 21 | P-controller |
|
68.151 | RCP 30, 31 | P+PI cascade controller |
|
68.210 | RCP 40 | Damper control unit |
|
46.103 | RDB 300 | Operating unit for RDT 300 |
|
65.010 | RDP 80 | Averaging relay |
|
46.100 | RDT 100 | Electronic ctrlr. for ventilation & air-con |
|
46.999 | RDT 200 | Electronic ctrlr. for ventilation & air-con | NO PDS |
46.102 | RDT 300 | Electronic ctrlr. for ventilation & air-con |
|
46.201 | RDT 708 | Ctrlr for vent.& air-cond for compact sys |
|
46.205 | RDT 711 | Ctrlr for vent.& air-con advanced funct's |
|
46.210 | RDT 724 | Ctrlr vent. air cond communic., universal |
|
43.125 | RLE 150 | Room-pressure controller |
|
43.124 | RLE 152 | Volume-flow controller, continuous |
|
67.301 | RLP 10 | Pneumatic volume-flow controller |
|
67.320 | RLP 10 F9.. | Pneumatic volume-flow transducer |
|
67.400 | RLP 100 | Pneumatic air-volume controller |
|
67.440 | RLP 100 F9.. | Dual-channel air-volume controller |
|
67.420 | RLP 100 F9.. | Pneum. room-pressure controller |
|
67.430 | RLP 100 F9.. | Pneumatic volume-flow transducer |
|
65.025 | RPJP 80 | PI relay |
|
68.240 | RPP 20 | P-controller |
|
65.052 | RUEP 5 | Electro-pneumatic relay |
|
68.451 | RUP | Differential-pressure controller/transducer |
|
65.150 | RVP 11 | Volume-amplifying relay |
|
65.015 | RVP 80 | Amplifying relay |
|
65.020 | RWP 80 | Reversing relay |
|
43.150 | RXE 101 | Air-volume adding unit |
|
67.500 | RXP 101 | Air-volume adding relay |
|
67.525 | RXP 200 | Pneum. Dual-channel, VAV master controller |
|
67.531 | RXP 210 | Air-volume alarm unit |
|
67.535 | RXP 212 | Pneumatic operating unit |
|
67.100 | RXP 81 | Pneumatic master controller |
|
39.001 | Schutzrohre | LW7, LW15 |
|
29.001 | Schutzrohre | LW7, LW15 |
|
32.010 | SDU 101 | Fine-differential-pressure transducer |
|
37.100 | SGU 100 F001 | Sash sensor |
|
44.535 | STU 101 | Electr. multiplier/converter for temp. data |
|
32.020 | SVU 100 | Air-flow transducer |
|
99.501 | SWMP36/24USB | novaPro |
|
產(chǎn)品系列:
If you can not read the text on these pages please download the free Chinese (simplified) font from Microsoft. Download here. |
|
產(chǎn)品系列:
能源與數(shù)據(jù)傳輸
處理系統(tǒng)
緩沖器
Energy & Data transmission |
| ||
|
| ||
|
| ||
|
| ||
|
| ||
|
| ||
|
| ||||||
|
| ||
|
| ||
|
Handling Systems |
| ||
|
| ||
|
| ||||||||
|
| ||||||||||
|
| ||||||
|
| ||||||||||||||||||||||||||||||
|
產(chǎn)品系列:
氣體調(diào)壓器:R 50 R 100 R 101 RS 250 RS 251
安全切斷閥: S 50 S 100
安全泄壓閥: SL 10
Gas Pressure Regulator type R 50
Description
The gas pressure regulator type R 50 serves to ensure constant outlet pressure at varying flow capacity. The single seat valve depends on the inlet pressure. Therefore it is necessary to take corrections at the setting spring in case of larger variations of the inlet pressure.
Because the diaphragm is only loaded by the spring power a quick regulation of the pressure is ensured.
Technical specifications
Inlet pressure Pe: | max. 3 bar | |
Outlet pressure Pa: | max. 1,2 bar | |
Connection: | R 1", R 1½" and R 2" | |
Single-seated valve Gas-tight zero position | ||
CE-No.: | 085BR0220 |
Gas Pressure Regulator type R 100*
Description
The gas pressure regulator type R 100* serves to ensure a constant outlet pressure when the inlet pressure or flow capacity varies. Design and construction of this unit allow for many applications. So the regulator can be used not only in gas distribution systems but also primarily in industrial gas burners and ovens where a short response time is required. Because of the exclusive use of spring loads, the installation is possible in any position.
Function:
The gas flows through the regulator housing in arrow direction. The main diaphragm is actuated via an impulse line from the outlet side by pressure. The required outlet pressure is adjusted at the spring. The valve remains open as long as the outlet pressure is below the set value. When reaching the set point the regulator valve closes.
Technical specifications
Inlet pressure Pe: | up to DN 150 up to max. 4 bar; DN 200 up to max. 1 bar | |
Outlet pressure Pa: | up to DN 150 up to max. 1,2 bar; DN 200 up to max. 750 mbar | |
Valve size: | DN 50 up to DN 200 | |
Flange connection: | PN 16 for DN 50 up to DN 150; PN 10 for DN 200 | |
Double-seated valve Ga-tight zero position | ||
* Also available as rotary regulator R 100 U and vacuum regulator R 100 UD | ||
CE-No.: | 0085AQ0410 |
Request for product information
Data sheet (1,1 MB)
Certificate acc. to Pressure Equipment Directive (148 kb)
Certificate acc. to. Gas Appliances Directive (154 kb)
Gas Pressure Regulator type R 101*
Description
The gas pressure regulator type R 101* serves to ensure a constant outlet pressure when the inlet pressure or flow capacity varies.
The gas pressure regulator is primarily used in industrial ovens and similar facilities where a short response time is required.
Function:
The gas flows through the regulator housing in arrow direction. The main diaphragm is actuated via an impulse line from the outlet side by pressure. The required outlet pressure is adjusted at the spring. The measurework is directly mounted and operates independant from the inlet pressure by use of an intermediate diaphragm.
Technical specifications
Inlet pressure Pe: | up to max. 4 bar | |
Outlet pressure Pa: | max. 1,2 bar | |
Valve size: | DN 25 up to DN 100 | |
Flange connection: | PN 16 | |
Single-seated valve with primary pressure equalisation Gas-tight zero position | ||
* Also available as R 101 US relife pressure valva for very low opening pressure | ||
Valve size: | DN 40 up to DN 200 | |
CE-No.: | 0085AQ0881 |
Request for product information
Data sheet (1,13 MB)
Certificate acc. to Pressure Equipment Directive (147 kb)
Certificate acc. to. Gas Appliances Directive (155 kb)
Gas Pressure Regulator type RS 250
With built in safety shut-off valve
Description
The gas pressure regulator type RS 250 serves to ensure a constant outlet pressure when the inlet pressure or flow capacity varies. The gas pressure regulator is primarily used in industrial ovens and similar facilities where a short response time is required. Because of the exclusive use of spring loads, the installation is possible in any position. The safety shutoff valve (SSV) which is built into the same housing interrupts the gas flow at excess pressure or gas shortage. If no SSV is built in the opening of the housing is closed with a cover plate. In this case the type designation is R 250.
Function:
The gas flows through the regulator housing in arrow direction. The main diaphragm is actuated via an impulse line from the outlet side by pressure. The required outlet pressure is adjusted at the spring. The single seat valve is directly mounted and operates independant from the inlet pressure by the compensation diaphragm. The diaphragm of the safety shutoff valve is actuated via an impulse line from the outlet side. When excess pressure or gas shortage lifts or drops the measure work the latch lever reacts and the closing spring presses the valve disc against the valve seat.
Application Example:
Gas train with gas pressure regulator RS and safety blow-off valve SL10
Technical specifications
Inlet pressure Pe: | up to DN 150 up to max. 6 bar DN 200 up to max. 4 bar | |
Outlet pressure Pa: | max. 1,2 bar | |
Valve size: | DN 25 up to DN 200 | |
Flange connection: | PN 16 up to DN 150; PN 10 for DN 200 (8 bore flange) | |
Single-seated valve with primary pressure equalisation Gas-tight zero position | ||
CE-No.: | 0085AQ0882 |
Request for product information
Data sheet (1,82 MB)
Certificate acc. to Pressure Equipment Directive (159 kb)
Certificate acc. to. Gas Appliances Directive (171 kb)
Gas Pressure Regulator type RS 251
With built in safety shut-off valve
Description
The gas pressure regulator type RS 251 serves to ensure a constant outlet pressure when the inlet pressure or flow capacity varies. The gas pressure regulator is primarily used in industrial ovens and similar facilities where a short response time is required. Because of the exclusive use of spring loads, the installation is possible in any position. The safety shutoff valve (SSV) which is built into the same housing interrupts the gas flow at excess pressure or gas shortage. If no SSV is built in the opening of the housing is closed with a cover plate. In this case the type designation is R 251.
Function:
The gas flows through the regulator housing in arrow direction. The main diaphragm is actuated via an impulse line from the outlet side by pressure. The required outlet pressure is adjusted at the spring. The single seat valve is directly mounted and operates independant from the inlet pressure by the compensation diaphragm. The diaphragm of the safety shutoff valve is actuated via an impulse line from the outlet side. When excess pressure or gas shortage lifts or drops the measure work the latch lever reacts and the closing spring presses the valve disc against the valve seat.
Application Example:
Gas train with gas pressure regulator RS and safety blow-off valve SL10
Technical specifications
Inlet pressure Pe: | up to max. 4 bar | |
Outlet pressure Pa: | max. 1,2 bar | |
Valve size: | DN 50 up to DN 100 | |
Flange connection: | PN 16 | |
Single-seated valve with primary pressure equalisation Gas-tight zeor position | ||
CE-No.: | 0085AQ0883 |
Request for product information
Data sheet (1,24 MB)
Certificate acc. to Pressure Equipment Directive (151 kb)
Certificate acc. to. Gas Appliances Directive (156 kb)
Safety Shut-off Valve type S 50
Description
The safety shutoff valve Type S 50 controls a given gas pressure. It interrupts the gas flow at excess pressure or gas shortage automatically. It may be used as a single safety device or in connection with the gas pressure regulator R 50 as a pressure controlling unit.
Function:
The diaphragm of the safety shutoff valve is actuated via an impulse line from the outlet side. When excess pressure or gas shortage lifts or drops the SSV spindle the latch lever reacts and the closing spring presses the valve disc against the valve seat. Minimum and maximum release pressure are set by adjusting the respective setting screws.
Technical specifications
Operating pressure: | 3 bar | |
Release: | lack of pressure and overpressure | |
Connection: | R 1", R 1½" and R 2" | |
Spring load Single-seated valve Ga-tight zero position | ||
CE-No.: | submitted |
Request for product information
Safety Shut-off Valve type S 100
Description
The safety shut-off valves (SSV) type S 100 control a given gas pressure. They interrupt the gas flow at excess pressure or gas shortage automatically. Design and construction of this unit allow for many applications. It may be used as a single safety device or in connection with the gas pressure regulators R 100/R 101 as a pressure controlling unit.
The installation is possible in any position.
Technical specifications
Inlet pressure Pe: | max. 4 bar | |
Release: | lack of pressure and overpressure | |
Valve size: | DN 25 up to DN 200 | |
Flange connection: | PN 16 for DN 25 up to DN 150; PN 10 for DN 200 | |
Gas-tight zero position | ||
CE-No.: | 0085AQ0880 |
Request for product information
Certificate acc. to Pressure Equipment Directive (150 kb)
Certificate acc. to. Gas Appliances Directive (163 kb)
Safety Relief Valve type SL 10
Description
The safety relief valves/safety blow-off valves (SBV)/safty exhaust valves type SL 10 prevent short pressure peaks in front of gas appliances or avoid inadmissable high increase of pressure caused by leakage gas.
Application Example:
Gas train with gas pressure regulator RS and safety blow-off valve SL10
Technical specifications
Blow-off pressure Pö: | 3.000 mbar | |
Connection: | R 1", R 1½" and R 2" | |
Single-seated valve Gas-tight zero position | ||
CE-No.: | 0085AQ0879 |
Request for product information
Data sheet (713 kb)
Certificate acc. to Pressure Equipment Directive (150 kb)
Certificate acc. to. Gas Appliances Directive (163 kb)